Philips | Various | Sound but no picture | Have found on some Philips | s if they are older then 15 years that a 2.7r resistor close to the HT transformer goes open, resulting in sound but no picture | |
Rca | Various | After presing play picture appears but looks like in pause mode | Clean and lubricate the capstan flywheel | ||
Sharp | VARIOUS | El mecanismo de transporte de la cinta pierde velocidad. | Rodillo del cabrestante or banda del cabrestante | ||
Various | Various | No capstan rotation / flatpack motors | Had this a lot, electrolytic cap on pcb leaks, replace cap but clean off area and check for o/c print eaten away by electrolyte from the little devil ... | ||
Samsung | Various | Entering Service Modes | Press standby, display, menu, mute, standby | ||
Samsung | Various | Entering Service Modes | Press standby, display, menu, mute, standby Press standby, picture standard, help, sleep, standby | ||
Philips | Various | Accessing service mode | try pressing the following keys on the user remote control- 0,6,2,5,9,6,OSD | ||
Onwa | Various | The Onwa TV PSU | See TV Mag Feb 1998 | ||
Onwa | various | Int dead / fizzing | Check HT relay | ||
Mitsubishi | Various | Int RGB variations/fback lines | Dry joints crt base | ||
LG | Various | Modifying R/C to access service modes | There is a service remote availiable but if you have a remote which uses an SAA3010T IC , simply connect a tact switch between pins 1 & 11 to access the service mode . | ||
BPL | Various | Field top foldover | 220R res over scan coils o/c | ||
Beko | Various | Field top foldover | 220R res over scan coils o/c | ||
Beko | Various | Field collapse | Check R717 & R722 for o/c | ||
B & O | Various | Dead - Tr1 in PSU s/c | Check C12 for dry joint in snubber of psu | ||
Akai | Various | To enter service mode | Press Mute, OK, TV in sequence |